Attenuation of Coaxial Transmission Lines 
  LMR-1200 LMR-900 LMR-600 1/2” LMR-400 Belden 9914 RG214 LMR-240 Belden LMR-200 LMR-195 RG-58/U
Superflex 9913F7 RG213 RG8X
Freq/Size 1.200” 0.870” 0.590” 0.520” 0.405” 0.405” 0.400” 0.405” 0.240” 0.242” 0.195” 0.195” 0.195”
30 MHz 0.209 0.288 0.421 0.561 0.7 0.8 0.8 1.2 1.3 2 1.8 1.8 2.5
50 MHz 0.272 0.374 0.547 0.73 0.9 1.1 1.1 1.6 1.7 2.5 2.3 2.3 3.1
150 MHz 0.481 0.658 0.964 1.29 1.5 1.7 1.7 2.8 3 4.7 3.9 4 6.2
220 MHz 0.589 0.803 1.18 1.58 1.8 2.1 2.1 3.5 3.7 6 4.8 4.8 7.4
450 MHz 0.864 1.17 1.72 2.32 2.7 3.1 3.1 5.2 5.3 8.6 6.9 7 10.6
900 MHz 1.27 1.7 2.5 3.41 3.9 4.4 4.5 8 7.6 12.8 9.9 9.9 16.5
1,500 MHz 1.69 2.24 3.31 4.57 5.1 6     9.9   12.7 12.9  
Coax losses shown above are for 100 feet lengths. Loss is a length multiplier, so a 200 ft length would have twice the loss shown above
and a 50 ft length would have half the loss. Keep cable installation lengths between radios and antennas as short as possible.